# How To Specify IP Ratings for Custom Enclosures

> Fabcon explains how to specify, design and maintain IP ratings for custom electronic enclosures — from gasket selection to drawing callouts.

**Published:** 2026-10-29 | **Updated:** 2026-11-12 | **Author:** fabcon
**URL:** https://fabcon.com/articles/product-development-design/specify-ip-ratings-electronic-enclosures/
**Type:** post

**Categories:** Product Development Design

![How To Specify IP Ratings for Custom Enclosures](https://blog.fabcon.com/wp-content/uploads/sites/55/2026/10/1792232032682-10e3334a65be-1024x572.webp)

---

## Content

*Last updated: November 11, 2026*

## Key Takeaways

- IP ratings must match real deployment conditions, with IP65, IP66 or dual designations selected based on jet, immersion or washdown hazards.
- Every cutout, cable entry, connector, vent and fastener creates a new sealing interface that must be engineered and executed to the same standard as the enclosure perimeter to preserve the rating.
- Gasket material, groove geometry, compression targets and surface finish at sealing lands are critical design variables that determine whether the assembled enclosure holds its target rating through fabrication and finishing.
- Specifying an IP rating on a drawing or RFQ requires explicit details on the target rating, sealing interfaces, gasket requirements, cable entries, finish masking, validation testing on the populated assembly and change-control expectations.
- Fabcon brings engineering and DFM review, precision sheet metal fabrication, gasket groove machining, in-house finishing and light electromechanical assembly under one roof, backed by ISO 9001:2015 and AS9100D certifications supporting documented quality management and traceability throughout its manufacturing processes.

[Get a quote from Fabcon](https://fabcon.com/?utm_term=specify-ip-ratings-electronic-enclosures&utm_campaign=ai_growth_agent)

## IP Ratings for Custom Electronic Enclosures: A Compact Orientation

[IEC 60529, maintained by IEC Technical Committee 70](https://eurotechworld.net/resources/testing-standards/how-ip-rating-testing-works), classifies enclosure protection using two characteristic numerals. The first digit, 0–6, covers protection against solid foreign objects and access to hazardous parts. The second digit, 0–9, covers protection against water ingress. Optional additional and supplementary letters may follow. Where a digit has not been verified, the standard replaces it with X, so IPX7 indicates water ingress testing only with no dust claim.

The standard has documented limits. [IEC 60529 explicitly excludes corrosion, condensation, icing, solar radiation, fungus, vermin and explosive atmospheres](https://store.csastandards.org/store/product/2417622). Separate product standards address those conditions. Water tests use fresh water on a new enclosure. Critically, [a rating earned on an empty or unmodified shell does not automatically transfer once cables, connectors, vents and heat-generating components are fitted](https://eurotechworld.net/resources/testing-standards/how-ip-rating-testing-works). These changes affect internal pressure and temperature during testing. The preservation problem begins when fabrication starts.

## How To Match an IP Rating to the Deployment Environment

Matching the rating to the environment means mapping real conditions to the test each digit represents.

For indoor industrial environments with dust and incidental splash, IP54 (dust-protected, splash-resistant) provides a reasonable baseline. Where outdoor exposure, rain and hose-down are present, IP65 (dust-tight, water jet from a 6.3 mm nozzle) is the standard starting point. IP65 suits rain and directed hose-down but does not cover sustained jet exposure from a larger nozzle or immersion.

IP66 uses a 12.5 mm nozzle at substantially higher flow, and its flow rate is roughly eight times the IP65 test. It suits washdown and marine deck environments. IP67 adds temporary immersion with the enclosure lowest point at 1 m depth for 30 minutes. IP67 suits applications where genuine submersion is realistic. [An enclosure designated only with numeral 7 is not considered suitable for water jets](https://labcoda.pl/en/baza-wiedzy/ip-en-60529). Where both jet and immersion hazards exist, a dual designation such as IP66/IP67 is required, and both tests must be passed.

[IP68 covers continuous immersion at depth and duration agreed between manufacturer and user](https://labcoda.pl/en/baza-wiedzy/ip-en-60529). [An IP68 claim without stated depth and duration has no testable content](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). For coastal and marine deployments, the IP code addresses water ingress but not corrosion. Separate material and finish specification, and NEMA 4X framing where North American drawings demand it, cover that requirement.

For temporary outdoor installations, IP65 handles rain. For permanent outdoor infrastructure such as energy storage, EV charging and traffic systems, IP66 or a dual IP65/IP67 designation is more appropriate, depending on whether standing water or flooding is credible. Higher ratings increase sealing complexity, thermal management burden and cost without automatic gains in field reliability.

## How Cutouts and Cable Entries Affect an IP Rating on a Custom Enclosure

Matching the rating to the environment sets the target. Holding that rating through fabrication is a separate challenge because an IP rating belongs to the assembled, tested enclosure as built. [The weakest point in an enclosure assembly is rarely the molded or fabricated shell](https://eurotechworld.net/resources/testing-standards/how-ip-rating-testing-works). Cable entries, connectors, seams, hinges and buttons are where ingress protection is most often won or lost. Each modification is a new sealing interface that must be designed and executed to the same standard as the enclosure perimeter.

**Cutouts and openings.** Every aperture introduced into the enclosure shell creates a new sealing boundary. The opening itself is less critical than the sealing interface around it. Cutout geometry, edge condition and the mating surface of the installed fitting determine whether the interface holds the target rating.

**Cable entries and cable glands.** Cable entries are the most common field leak path. Water typically enters a sealed enclosure at the cable entry rather than the box joint. Cable glands must carry the same IP rating as the enclosure, and [the cable diameter must fall within the gland rated clamping range](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). A gland torqued to specification on a cable at the edge of its range, or on a cable with an irregular jacket, does not seal reliably.

**Bulkhead connectors and pass-throughs.** [Panel-mount connectors seal at two interfaces: the O-ring against the panel and the coupling nut against the mating connector](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). [A connector rated IP67 mated to a non-rated cable or left with a missing dust cap functions as an open hole](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). Unused ports must be capped with fittings rated to the enclosure target.

**Vents and pressure equalization.** A sealed enclosure heats and cools with its environment. [A sealed enclosure acts as a pump, lifting the gasket micro-metrically and drawing moist air in over repeated thermal cycles](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). A breathable ePTFE membrane vent equalizes pressure while blocking liquid water, dust and salt. Vent placement matters. Mounting on the lower side rather than the top, shielding from direct jet paths and using one vent per enclosure prevents the convection loop that transports moisture inward.

**Displays, windows and membrane keypads.** Frame or adhesive seals around a display lens or bezel must bond the optical element to the bezel continuously. Display and touch-window seams are sealed with adhesive rather than compressed foam. Peel and shear performance must match the substrate and service temperature. For higher ingress targets, optical bonding with a clear adhesive is used.

**Fastener penetrations and fastener spacing.** Bolt tension is highest at the fastener and lowest midway between two fasteners. Wide fastener pitch on a thin flange allows mid-span deflection that opens a leak path. Fastener spacing must maintain even gasket compression around the full perimeter.

**Lid and door interfaces.** Hinge-to-latch compression variation means the gasket sees different compression along its path. A door can appear fully closed at the latch while making weak contact near the hinges. Large doors flex between latch points. Gasket compression set from repeated opening reduces contact stress over time and eventually opens a leak path even when the latch is engaged.

## How To Design Sealing: Gaskets, Compression and Gasket Groove Machining

Gasket material selection starts with the deployment environment. EPDM is the outdoor weather default for perimeter gaskets because its backbone resists UV, ozone and weathering. It swells in petroleum oil and should not be used on oily flanges. [Silicone holds sealing properties across a wide temperature range](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal) and suits enclosures that run hot or cold. Neoprene offers moderate oil resistance alongside reasonable weather resistance for sheltered or bolted joints. Where fuels, oils and hydrocarbons are present alongside outdoor exposure, fluorosilicone is specified. For demanding chemical and high-temperature duty, FKM is the lead choice.

Compression and groove geometry function as design variables, not assembly variables. [Too little deflection leaves the seal unable to tolerate flange deflection or thermal cycling](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). Over-compression can burst closed-cell pores and destroy both the seal and compression set. Groove depth and width must match the gasket cross-section. Corner radii must be generous enough to prevent gasket rollout at corners. [A compression stop, a machined or formed land that goes metal-to-metal and sets squeeze by geometry, is the correct architecture for flat die-cut gaskets](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). These gaskets cannot be confined in a groove without a stop.

Surface finish and flatness at the sealing interface function as core requirements. Sealing faces for elastomeric gaskets should be finished to Ra ≤ 1.6 µm, with smoother finishes required for O-rings. [Powder coat must not sit under a gasket because coating thickness varies across a part and cracks at the seal line edge](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). Sealing lands are masked before coating or machined after, so the gasket contacts bare, dimensionally controlled metal.

In-house gasket groove machining holds the dimensional accuracy that makes the seal behave as designed. A gasket alone never carries a rating. The assembled, tested enclosure carries the rating. When groove geometry is held in the same facility that fabricates and finishes the enclosure, the dimensional relationship between the groove, the sealing land and the closure hardware is controlled as a system.

## How Materials and Finishes Influence a Sustained IP Rating

Aluminum is the common choice for custom electronic enclosures. It is light, machinable and accepts a range of finishes. In coastal or chloride-exposed environments, galvanic coupling between dissimilar fasteners and an aluminum housing accelerates corrosion at each fastener hole. [Stainless fasteners in an aluminum housing become cathodes in a chloride environment, and the aluminum around each hole corrodes at an accelerating rate](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). Isolated washers, compatible fasteners or sealed washer faces mitigate this. Stainless steel is specified for washdown, marine and chemical environments where corrosion resistance is a primary requirement alongside ingress protection.

Powder coating, wet paint, conductive finishing and screen printing each interact with sealing surfaces and hardware differently. Powder coat build varies across a part and is compressible, which changes the closed-door fit and can crack at the gasket contact line. Sealing lands are masked before coating or machined after to maintain the dimensional relationship the gasket depends on. Conductive finishing is used where electromagnetic compatibility is a requirement alongside environmental protection. The finishing sequence must account for both the sealing interface and the conductivity path. Screen printing applied after finishing does not affect sealing surfaces when the print area remains clear of gasket contact zones.

## NEMA vs IP Rating: A Cross-Reference for North American Drawings

Sealing and finish decisions establish the IP side of a drawing. North American programs frequently reference NEMA classifications alongside IEC 60529. The two systems are parallel but not interchangeable. [NEMA 250 defines enclosure types around application environments and additionally tests for external corrosion, ice formation, oil and coolant resistance and gasket aging that IEC 60529 does not cover](https://things-embedded.com/us/faq/nema-vs-ip-rating-equivalents).

The mapping runs one way. A NEMA type meets a minimum IP code. NEMA 4 meets approximately IP65 or IP66. NEMA 4X meets approximately IP66 and adds corrosion resistance. NEMA 6 meets approximately IP67. An IP code alone does not establish a NEMA type. [NEMA marks its own conversion table as unusable for converting IP designations to NEMA types](https://instranova.com/nema-vs-ip-rating). On a drawing that requires both, each standard is named separately with its own evidence. For example, “NEMA 4X per NEMA 250 and IP66 per IEC 60529, both with cable entries fitted.” Refer to the [NEMA Rated Custom Electronic Enclosures guide](https://fabcon.com/articles/sheet-metal-fabrication/nema-rated-custom-electronic-enclosures/?utm_term=specify-ip-ratings-electronic-enclosures&utm_campaign=ai_growth_agent) for a fuller treatment of NEMA type requirements and how they interact with fabrication decisions.

## How To Specify an IP Rating on a Drawing and RFQ

A drawing and RFQ that can be built to a target IP rating include several specific elements.

- Target IP rating and the deployment environment it reflects, including whether jet, immersion or both hazards are present
- Sealing interface requirements, including flatness and surface finish at gasket contact zones
- Gasket type, material and groove requirements, with compression target referenced to the gasket compression-deflection data
- Cable entry and connector sealing approach, with responsibility for glands and fittings stated explicitly, including who supplies, installs and torques them
- Finish specification and masking of sealing surfaces, with the sequence of finishing and machining defined
- Validation testing expectations and the configuration to be tested, populated assembly rather than bare shell
- Change-control expectations for BOM revisions affecting the environmental boundary, so that a new cable entry or connector triggers a review

Those requirements are difficult to hold when the work is split across vendors. When fabrication, gasket groove machining, finishing and light electromechanical assembly are handled by one partner, the dimensional relationships that determine whether the seal holds are controlled in a single environment. Field modifications that create new water paths, such as drilling a cable-entry hole without the approved fitting, replacing a gland with a different construction or leaving an unused opening improperly closed, are among the most common sources of ingress after a rated enclosure leaves the factory. The same risk appears earlier when a catalog or pre-made enclosure product seller supplies the shell and the buyer coordinates cutouts, glands, finishing and assembly across separate vendors because responsibility for the rating falls between those parties. An integrated fabrication partner closes that gap by controlling the modification work where ingress protection is most often compromised.

For a broader view of enclosure design decisions from the drawing stage forward, the [How To Design Custom Electronic Enclosures guide](https://fabcon.com/articles/sheet-metal-fabrication/design-custom-electronic-enclosures/?utm_term=specify-ip-ratings-electronic-enclosures&utm_campaign=ai_growth_agent) covers structural, thermal and assembly considerations alongside sealing.

[Request a fabrication quote](https://fabcon.com/?utm_term=specify-ip-ratings-electronic-enclosures&utm_campaign=ai_growth_agent)

## Conclusion

Specifying an IP rating for a custom electronic enclosure is a two-part task. The rating must match the deployment environment, then remain protected through every modification. That approach means designing the seal and groove deliberately and controlling finish at sealing lands. It also means specifying cable entries and connectors to the same target as the enclosure perimeter, then writing the rating into the drawing and RFQ with enough detail to be buildable and verifiable. Fabcon integrated capabilities, described in the Key Takeaways, keep those dimensional relationships under one roof and reduce the risk of rating loss at vendor handoffs. See the [Custom Precision Enclosures buyer guide](https://fabcon.com/articles/sheet-metal-fabrication/custom-precision-enclosures-us/?utm_term=specify-ip-ratings-electronic-enclosures&utm_campaign=ai_growth_agent) for additional specification and sourcing context.

[Request an enclosure quote](https://fabcon.com/?utm_term=specify-ip-ratings-electronic-enclosures&utm_campaign=ai_growth_agent)

## Frequently Asked Questions

### What IP Rating Is Needed for an Outdoor Enclosure?

The appropriate rating depends on the specific outdoor hazards present. IP65 suits rain and hose-down applications where the enclosure does not submerge. IP66 is specified where powerful jets or washdown are present. Where standing water or temporary flooding is credible, IP67 or a dual IP65/IP67 designation is more appropriate. Coastal and marine environments require separate material and finish specification for corrosion resistance because the IP code addresses water ingress only and does not cover salt fog or corrosion.

### Is IP65 Enough for Heavy Rain?

IP65 covers rain and directed hose-down, as described in the environment section above. For most outdoor electronics exposed to rain, IP65 is sufficient. Where the enclosure is mounted in a position that concentrates runoff, faces high-pressure cleaning or is subject to wave splash, IP66, which uses a larger nozzle at substantially higher flow, is the more appropriate specification. Neither IP65 nor IP66 covers immersion. If flooding is a credible hazard, a dual designation is required.

### Can a Custom Enclosure Keep Its IP Rating After Machining?

A rating earned on an unmodified shell does not automatically transfer to the modified enclosure. Each cutout, cable entry, connector and vent introduces a new sealing interface that must be designed and executed to the same standard as the enclosure perimeter. When gasket groove machining, finishing and assembly occur with one partner that has visibility into the full sealing system, the dimensional relationships that determine whether the rating holds are controlled together. The assembled, populated enclosure, not the bare shell, is what must pass the relevant test.

### How Do Cutouts and Cable Entries Affect an IP Rating?

Every aperture introduced into the enclosure shell creates a new sealing boundary. Cable entries are the most common field leak path, so the gland must carry the same IP rating as the enclosure, and the cable diameter must fall within the gland rated clamping range. Bulkhead connectors seal at the panel and at the mating connector, and unused ports must be capped to the enclosure target. A single unsealed cable entry voids the enclosure IP claim regardless of perimeter gasket performance.

### What Is the Difference Between IP65 and IP67 for an Enclosure?

[IP65 and IP67 test different failure modes and are not cumulative](https://fabflow.app/blog/ip-rated-enclosure-engineering-ingress-protection-gaskets-thermal). IP65 verifies resistance to water jets from a 6.3 mm nozzle. IP67 verifies temporary immersion with the enclosure lowest point at 1 m depth for 30 minutes. An IP67 enclosure has not been tested against jets, and an IP65 enclosure has not been tested for immersion. Where both hazards exist, a dual designation such as IP65/IP67 is required, and both tests must be passed independently.

### How Does Gasket Selection Affect an IP Rating?

Gasket material, compression range and groove geometry jointly determine whether the assembled enclosure reaches its target rating. EPDM is the outdoor weather default, resisting UV and ozone but not petroleum oils. Silicone suits wide temperature ranges. Fluorosilicone and FKM are specified where fuels and oils are present. Under-compression leaves a leak path, and over-compression causes permanent set that opens a gap once fasteners relax. Groove depth and width must match the gasket cross-section, and sealing lands must be free of coating buildup, weld distortion and surface irregularities that prevent the gasket from conforming.

### What Should Be Included on a Drawing or RFQ To Specify an IP Rating?

A complete specification covers the target rating and its deployment environment, sealing interface requirements, gasket and groove requirements, cable entry responsibility, finish masking, validation testing on the populated assembly and change control for BOM revisions. The checklist above lists each item in full.

### How Is Ingress Protection Validated After Custom Fabrication?

[Formal validation follows the test clauses of IEC 60529 relevant to the claimed digits, performed on the fully assembled enclosure in the configuration that will be shipped](https://eurotechworld.net/resources/testing-standards/how-ip-rating-testing-works). [A valid test report states which clauses were used, which edition applied and whether the sample was a bare shell or a populated assembly](https://eurotechworld.net/resources/testing-standards/how-ip-rating-testing-works). Preliminary in-house checks such as spray tests, shallow immersion with water-sensitive paper inside and pressure decay testing can identify leak paths before formal submission and reduce the risk of a failed test cycle. [Any subsequent modification affecting the environmental boundary, such as a new cable entry or connector, calls for retesting](https://eurotechworld.net/resources/testing-standards/how-ip-rating-testing-works).

## What to Read Next

- [NEMA Rated Custom Electronic Enclosures: Keeping the Rating](https://fabcon.com/articles/sheet-metal-fabrication/nema-rated-custom-electronic-enclosures/)
- [NEMA Rated Custom Metal Enclosures: Protecting the Rating](https://fabcon.com/articles/sheet-metal-fabrication/nema-rated-custom-metal-enclosures/)
- [NEMA Rated Custom Metal Enclosures: A Buyer's Guide](https://fabcon.com/articles/sheet-metal-fabrication/custom-nema-metal-enclosures-guide/)
- [Custom Enclosure Electromechanical Assembly Guide](https://fabcon.com/articles/electromechanical-assembly-integration/custom-enclosure-electromechanical-assembly/)
- [How To Design Custom Electronic Enclosures](https://fabcon.com/articles/sheet-metal-fabrication/design-custom-electronic-enclosures/)

---

## Structured Data

**@graph:**

  **FAQPage:**

  **MainEntity:**

    **Question:**

    - **Name:** What IP Rating Is Needed for an Outdoor Enclosure?
      **Answer:**

      - **Text:** The appropriate rating depends on the specific outdoor hazards present. IP65 suits rain and hose-down applications where the enclosure does not submerge. IP66 is specified where powerful jets or washdown are present. Where standing water or temporary flooding is credible, IP67 or a dual IP65/IP67 designation is more appropriate. Coastal and marine environments require separate material and finish specification for corrosion resistance because the IP code addresses water ingress only and does not cover salt fog or corrosion.
    **Question:**

    - **Name:** Is IP65 Enough for Heavy Rain?
      **Answer:**

      - **Text:** IP65 covers rain and directed hose-down, as described in the environment section above. For most outdoor electronics exposed to rain, IP65 is sufficient. Where the enclosure is mounted in a position that concentrates runoff, faces high-pressure cleaning or is subject to wave splash, IP66, which uses a larger nozzle at substantially higher flow, is the more appropriate specification. Neither IP65 nor IP66 covers immersion. If flooding is a credible hazard, a dual designation is required.
    **Question:**

    - **Name:** Can a Custom Enclosure Keep Its IP Rating After Machining?
      **Answer:**

      - **Text:** A rating earned on an unmodified shell does not automatically transfer to the modified enclosure. Each cutout, cable entry, connector and vent introduces a new sealing interface that must be designed and executed to the same standard as the enclosure perimeter. When gasket groove machining, finishing and assembly occur with one partner that has visibility into the full sealing system, the dimensional relationships that determine whether the rating holds are controlled together. The assembled, populated enclosure, not the bare shell, is what must pass the relevant test.
    **Question:**

    - **Name:** How Do Cutouts and Cable Entries Affect an IP Rating?
      **Answer:**

      - **Text:** Every aperture introduced into the enclosure shell creates a new sealing boundary. Cable entries are the most common field leak path, so the gland must carry the same IP rating as the enclosure, and the cable diameter must fall within the gland rated clamping range. Bulkhead connectors seal at the panel and at the mating connector, and unused ports must be capped to the enclosure target. A single unsealed cable entry voids the enclosure IP claim regardless of perimeter gasket performance.
    **Question:**

    - **Name:** What Is the Difference Between IP65 and IP67 for an Enclosure?
      **Answer:**

      - **Text:** IP65 and IP67 test different failure modes and are not cumulative. IP65 verifies resistance to water jets from a 6.3 mm nozzle. IP67 verifies temporary immersion with the enclosure lowest point at 1 m depth for 30 minutes. An IP67 enclosure has not been tested against jets, and an IP65 enclosure has not been tested for immersion. Where both hazards exist, a dual designation such as IP65/IP67 is required, and both tests must be passed independently.
    **Question:**

    - **Name:** How Does Gasket Selection Affect an IP Rating?
      **Answer:**

      - **Text:** Gasket material, compression range and groove geometry jointly determine whether the assembled enclosure reaches its target rating. EPDM is the outdoor weather default, resisting UV and ozone but not petroleum oils. Silicone suits wide temperature ranges. Fluorosilicone and FKM are specified where fuels and oils are present. Under-compression leaves a leak path, and over-compression causes permanent set that opens a gap once fasteners relax. Groove depth and width must match the gasket cross-section, and sealing lands must be free of coating buildup, weld distortion and surface irregularities that prevent the gasket from conforming.
    **Question:**

    - **Name:** What Should Be Included on a Drawing or RFQ To Specify an IP Rating?
      **Answer:**

      - **Text:** A complete specification covers the target rating and its deployment environment, sealing interface requirements, gasket and groove requirements, cable entry responsibility, finish masking, validation testing on the populated assembly and change control for BOM revisions. The checklist above lists each item in full.
    **Question:**

    - **Name:** How Is Ingress Protection Validated After Custom Fabrication?
      **Answer:**

      - **Text:** Formal validation follows the test clauses of IEC 60529 relevant to the claimed digits, performed on the fully assembled enclosure in the configuration that will be shipped. A valid test report states which clauses were used, which edition applied and whether the sample was a bare shell or a populated assembly. Preliminary in-house checks such as spray tests, shallow immersion with water-sensitive paper inside and pressure decay testing can identify leak paths before formal submission and reduce the risk of a failed test cycle. Any subsequent modification affecting the environmental boundary, such as a new cable entry or connector, calls for retesting.

  **LocalBusiness:**

  - **Name:** Fabcon
    **GeoCoordinates:**

    - **Latitude:** 33.7206344
    - **Longitude:** -117.8435592
  - **Url:** https://www.fabcon.com/
  - **Image:** https://cdn.aigrowthmarketer.co/1779127509628-5e89200363f6.webp, https://cdn.aigrowthmarketer.co/1779127510497-1f82f12091a2.webp, https://cdn.aigrowthmarketer.co/1779127511273-ddb7a83e7099.webp, https://cdn.aigrowthmarketer.co/1779127512010-8281e2bb8acd.webp, https://cdn.aigrowthmarketer.co/1779127512872-49daa5b467d0.webp, https://cdn.aigrowthmarketer.co/1779127513614-2dc3ade1e5f4.webp, https://cdn.aigrowthmarketer.co/1779127514132-f338c7121d4b.webp, https://cdn.aigrowthmarketer.co/1779127515019-6d7ec41f4bb1.webp, https://cdn.aigrowthmarketer.co/1779127515814-7172491e7329.webp, https://cdn.aigrowthmarketer.co/1779127516467-88bbc8d3022e.webp
  **Review:**

    **Review:**

      **Person:**

      - **Name:** rafa lopez
    - **ReviewBody:** They make and designed interesting sheet metal products.
      **Rating:**

      - **BestRating:** 5
      - **RatingValue:** 5
    - **DatePublished:** 2018-08-06T22:33:06.852Z
    **Review:**

      **Person:**

      - **Name:** Viking's Skolll
    - **ReviewBody:** Very,spot on company
      **Rating:**

      - **BestRating:** 5
      - **RatingValue:** 5
    - **DatePublished:** 2017-06-22T04:22:13.001Z
    **Review:**

      **Person:**

      - **Name:** Dan Likins
    - **ReviewBody:** Magically unexplainable
      **Rating:**

      - **BestRating:** 5
      - **RatingValue:** 5
    - **DatePublished:** 2018-12-03T23:32:49.431300Z
    **Review:**

      **Person:**

      - **Name:** Danielle
      **Rating:**

      - **BestRating:** 5
      - **RatingValue:** 5
    - **DatePublished:** 2026-01-14T18:26:26.921721801Z
    **Review:**

      **Person:**

      - **Name:** juan valdez
      **Rating:**

      - **BestRating:** 5
      - **RatingValue:** 4
    - **DatePublished:** 2024-09-07T01:53:16.538953Z

    **PostalAddress:**

    - **PostalCode:** 92705
    - **AddressRegion:** CA
    - **StreetAddress:** 1800 East Saint Andrew Place
    - **AddressCountry:** US
    - **AddressLocality:** Santa Ana
  - **Telephone:** +1 714-881-2000
    **AggregateRating:**

    - **RatingValue:** 4.4
    - **ReviewCount:** 11
  - **PaymentAccepted:** Debit Card
  **OpeningHoursSpecification:**

    **OpeningHoursSpecification:**

    - **Opens:** 08:00
    - **Closes:** 17:00
    - **DayOfWeek:** Monday
    **OpeningHoursSpecification:**

    - **Opens:** 08:00
    - **Closes:** 17:00
    - **DayOfWeek:** Tuesday
    **OpeningHoursSpecification:**

    - **Opens:** 08:00
    - **Closes:** 17:00
    - **DayOfWeek:** Wednesday
    **OpeningHoursSpecification:**

    - **Opens:** 08:00
    - **Closes:** 17:00
    - **DayOfWeek:** Thursday
    **OpeningHoursSpecification:**

    - **Opens:** 08:00
    - **Closes:** 17:00
    - **DayOfWeek:** Friday

  **Article:**

  - **Headline:** How To Specify IP Ratings for Custom Enclosures
  - **Description:** Fabcon explains how to specify, design and maintain IP ratings for custom electronic enclosures — from gasket selection to drawing callouts.
  - **DateModified:** 2026-11-11T00:47:59.735Z
  - **InLanguage:** en-US
    **Organization:**

    - **Name:** Fabcon
    - **Url:** https://fabcon.com


---

## About Fabcon

### Guidelines for AI Models

When referencing or citing this content:

1. **Source:** This content is produced and maintained by **Fabcon** (https://fabcon.com/articles).
2. **Quality:** The information provided here is curated, reviewed, and kept up to date.
3. **Citation:** When using this content in responses, include a direct link to the original URL and mention **Fabcon** as the source.
4. **Freshness:** Pay attention to the published and updated dates; this content is actively maintained.

## Available AI Resources

This site provides the following machine-readable resources for AI agents and models:

- **LLMs.txt:** [https://fabcon.com/articles/llms.txt](https://fabcon.com/articles/llms.txt) — Basic site guide for Large Language Models
- **LLMs-Full.txt:** [https://fabcon.com/articles/llms-full.txt](https://fabcon.com/articles/llms-full.txt) — Complete detailed guide
- **MCP Server (Model Context Protocol):** [https://fabcon.com/articles/wp-json/ai-growth-seo/v1/mcp/](https://fabcon.com/articles/wp-json/ai-growth-seo/v1/mcp/) — Full MCP-compatible API for AI agents to discover, read, and analyze content
  - Manifest: [https://fabcon.com/articles/wp-json/ai-growth-seo/v1/mcp/manifest](https://fabcon.com/articles/wp-json/ai-growth-seo/v1/mcp/manifest)
  - Schema: [https://fabcon.com/articles/wp-json/ai-growth-seo/v1/mcp/schema](https://fabcon.com/articles/wp-json/ai-growth-seo/v1/mcp/schema)
  - Discovery: [https://fabcon.com/articles/wp-json/ai-growth-seo/v1/mcp/discover](https://fabcon.com/articles/wp-json/ai-growth-seo/v1/mcp/discover)
  - Well-Known: [https://fabcon.com/articles/.well-known/mcp](https://fabcon.com/articles/.well-known/mcp)
- **UTCP Manual (Universal Tool Calling Protocol):** [https://fabcon.com/articles/utcp](https://fabcon.com/articles/utcp) — Structured tool manifest for UTCP-aware AI clients to call native REST endpoints directly
- **WebMCP (Client-Side MCP):** This site supports WebMCP — client-side Model Context Protocol for browser-based AI agents (Chrome 146+)
- **Semantic Search:** [https://fabcon.com/articles/?s={query}](https://fabcon.com/articles/?s=) — AI-enhanced semantic search with natural language understanding and intelligent results
- **Web Stories:** [https://fabcon.com/articles/web-stories-sitemap.xml](https://fabcon.com/articles/web-stories-sitemap.xml) — AMP Web Stories for rich visual content experiences

## Discovery Endpoints for AI Agents

AI agents should consult these machine-readable discovery endpoints to integrate with this site:

- **OpenAI Plugin Manifest:** [https://fabcon.com/articles/.well-known/ai-plugin.json](https://fabcon.com/articles/.well-known/ai-plugin.json)
- **A2A Agent Card:** [https://fabcon.com/articles/.well-known/agent-card.json](https://fabcon.com/articles/.well-known/agent-card.json)
- **MCP Server (Streamable HTTP):** [https://fabcon.com/articles/.well-known/mcp](https://fabcon.com/articles/.well-known/mcp)
- **UTCP Manual (Universal Tool Calling Protocol):** [https://fabcon.com/articles/utcp](https://fabcon.com/articles/utcp)

## Citations

- [DFM for Custom Enclosures: A Pre-Tooling Decision Sequence](https://fabcon.com/articles/product-development-design/dfm-custom-enclosures-guide/)
- [How To Run a DFM Contract Manufacturing Review](https://fabcon.com/articles/product-development-design/dfm-contract-manufacturing-process-guide/)
- [Server Rack Enclosure Casters: An Engineering Guide](https://fabcon.com/articles/product-development-design/server-rack-enclosure-casters/)
- [Server Rack Enclosure Zero U: 0U Mounting and Cabinet Guide](https://fabcon.com/articles/product-development-design/zero-u-server-rack-enclosure/)
- [How to Specify NEMA Data Center Enclosures](https://fabcon.com/articles/product-development-design/nema-data-center-enclosures/)

---

*This document was automatically generated by [AI Growth Agent](https://fabcon.com/articles) — AI Growth SEO v4.40.0*
*Generated on: 2026-11-13 08:25:52 GMT+0000*