{"id":749,"date":"2026-06-01T15:25:01","date_gmt":"2026-06-01T15:25:01","guid":{"rendered":"https:\/\/blog.fabcon.com\/uncategorized\/precision-sheet-metal-cabinets-2026\/"},"modified":"2026-09-02T05:06:42","modified_gmt":"2026-09-02T05:06:42","slug":"precision-sheet-metal-cabinets-2026","status":"publish","type":"post","link":"https:\/\/fabcon.com\/articles\/sheet-metal-fabrication\/precision-sheet-metal-cabinets-2026\/","title":{"rendered":"Precision Sheet Metal Fabrication for Data Center Cabinets"},"content":{"rendered":"<p><em>Last updated: August 31, 2026<\/em><\/p>\n<h2 id=\"key-takeaways\">Key Takeaways<\/h2>\n<ul>\n<li>Precision sheet metal data center cabinets are custom enclosures built to tight tolerances for structural strength, airflow and equipment security in high-density IT and AI deployments.<\/li>\n<li>Modern cabinets rely on advanced fabrication techniques to support heavier loads, move higher airflow volumes and integrate power and cooling systems while maintaining dimensional accuracy.<\/li>\n<li>Core components include structural frames, perforated doors with high open area, integrated cable pathways and PDU mountings that require precise manufacturing.<\/li>\n<li>Material choice between steel and aluminum, combined with finishes and thermal features, shapes cabinet weight, strength, corrosion resistance and cooling performance.<\/li>\n<li>Choosing a fabrication partner with ISO 9001 and AS9100D certifications and vertical integration is critical, and <a href=\"https:\/\/fabcon.com\/\" target=\"_blank\">Fabcon<\/a> supports programs from prototype through production.<\/li>\n<\/ul>\n<h2>Why Precision Fabrication Defines Modern Data Center Cabinets<\/h2>\n<p>Data center cabinets are no longer simple metal boxes. <a href=\"https:\/\/kdstelectrical.com\/data-center-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">Rack density increased in 2025<\/a> by the largest year-over-year margin ever recorded, which raised structural and thermal demands on enclosures.<\/p>\n<figure style=\"text-align: center\"><img decoding=\"async\" src=\"https:\/\/cdn.aigrowthmarketer.co\/1785163283863-18516e05d63b.webp\" alt=\"A data-center aisle lined with rows of server enclosures.\" style=\"max-height: 500px\" loading=\"lazy\"><figcaption><em>Modular, rack-mounted enclosures and structural systems that simplify cooling, cable management, and integration for hyperscale and edge data-center deployments.<\/em><\/figcaption><\/figure>\n<p>Precision sheet metal fabrication enables cabinets to support heavier loads, manage higher airflow volumes and integrate power and cooling systems while holding tight tolerances. Engineering and procurement teams need fabrication partners that deliver this precision consistently across every production run.<\/p>\n<p>This guide outlines the key components, materials, thermal strategies, DFM practices and supplier criteria that support reliable precision cabinets in modern data centers.<\/p>\n<h2>Key Components of Precision Data Center Cabinets<\/h2>\n<p>A precision data center cabinet is an engineered system, and understanding its core components helps teams specify requirements clearly and evaluate fabrication capabilities.<\/p>\n<h3>Structural Frame<\/h3>\n<p>The frame is the load-bearing skeleton. Precision fabrication maintains squareness, rail alignment and stiffness for fully populated racks. <a href=\"https:\/\/kdstelectrical.com\/42u-server-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">A fully loaded 42U server rack cabinet can support heavy networking equipment<\/a>. Frame integrity depends on steel gauge, weld quality and base construction.<\/p>\n<h3>Perforated Metal Doors<\/h3>\n<p>Front and rear perforated doors support passive ventilation. <a href=\"https:\/\/mjmmfg.com\/data-center-sheet-metal-fabrication\" target=\"_blank\" rel=\"noindex nofollow\">Modern high-density cabinets often use high open area on both doors, and hex perforation patterns provide strong structure at a given pitch compared with round patterns<\/a>.<\/p>\n<h3>Cable Pathways and PDU Mountings<\/h3>\n<p>Integrated brackets, vertical cable managers and custom PDU mounting provisions keep routing organized without blocking airflow. Precision fabrication builds these features into the cabinet design instead of treating them as later add-ons.<\/p>\n<h3>Common Cabinet Types and Their Uses<\/h3>\n<p>The main cabinet formats each bring distinct fabrication and deployment considerations.<\/p>\n<figure style=\"text-align: center\"><img decoding=\"async\" src=\"https:\/\/cdn.aigrowthmarketer.co\/1785163149014-90272e343944.webp\" alt=\"Three energy-storage enclosure cabinets in white, gray, and black.\" style=\"max-height: 500px\" loading=\"lazy\"><figcaption><em>Weatherproof, customizable enclosures with electromechanical integration for energy storage and power distribution \u2014 engineered for commercial and public deployments.<\/em><\/figcaption><\/figure>\n<ul>\n<li><strong>Enclosed cabinets:<\/strong> Full doors, side panels and top covers support security and environmental control.<\/li>\n<li><strong>Open-frame racks:<\/strong> Two-post or four-post bare frames favor maximum airflow in controlled rooms.<\/li>\n<li><strong>Seismic\/NEBS cabinets:<\/strong> Zone-rated reinforced structures support high-availability or telecom sites.<\/li>\n<\/ul>\n<h2>Standard Dimensions and Customization Options<\/h2>\n<p><a href=\"https:\/\/kdstelectrical.com\/42u-server-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">The EIA-310 standard defines the 19-inch mounting width at 482.6 mm and the rack unit height at 1.75 inches (44.45 mm)<\/a>. Beyond these mounting dimensions, cabinet envelope sizes shift based on application.<\/p>\n<p>The most common configurations for data center white space are:<\/p>\n<ul>\n<li><strong>Heights:<\/strong> <a href=\"https:\/\/kdstelectrical.com\/data-center-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">42U and 48U are the most common<\/a><\/li>\n<li><strong>Widths:<\/strong> <a href=\"https:\/\/kdstelectrical.com\/42u-server-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">600 mm and 800 mm are standard<\/a><\/li>\n<li><strong>Depths:<\/strong> <a href=\"https:\/\/kdstelectrical.com\/data-center-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">600 mm through 1,200 mm, with deeper options favored for modern servers and GPU or AI nodes<\/a><\/li>\n<\/ul>\n<p><a href=\"https:\/\/kdstelectrical.com\/data-center-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">For 2026 workloads, 48U cabinets with 1,000\u20131,200 mm depth support deeper servers, cable management and PDU clearance<\/a>. Precision fabrication supports customization beyond standard footprints with features such as custom cutouts and reinforced bases while maintaining dimensional accuracy.<\/p>\n<p>Tight tolerances on rail spacing and frame squareness protect rack-mount interoperability. A fabricator who understands which dimensions are critical adds more value than one who only executes drawings. Equally important is the choice of materials, which shapes weight, strength, corrosion resistance and cost.<\/p>\n<p><a href=\"https:\/\/fabcon.com\/\" target=\"_blank\"><strong>Discuss data center cabinet specifications with Fabcon.<\/strong><\/a><\/p>\n<h2>Materials and Finishes for Data Center Cabinets<\/h2>\n<p>Material selection directly affects weight, strength, corrosion resistance and cost. The two primary options, steel and aluminum, each present distinct trade-offs in these areas.<\/p>\n<h3>Steel<\/h3>\n<p><a href=\"https:\/\/bwsheetmetal.com\/data-center-server-rack-design\" target=\"_blank\" rel=\"noindex nofollow\">Cold-rolled carbon steel is the baseline material for indoor powder-coated server rack cabinets<\/a> because it balances strength and cost and forms easily. It supports frames and other load-bearing components. <a href=\"https:\/\/bwsheetmetal.com\/data-center-server-rack-design\" target=\"_blank\" rel=\"noindex nofollow\">Galvanized or galvannealed sheet can add corrosion resistance for selected sub-components, although zinc-based coatings require specific welding, pretreatment and edge repair practices<\/a>.<\/p>\n<h3>Aluminum<\/h3>\n<p><a href=\"https:\/\/mjmmfg.com\/data-center-sheet-metal-fabrication\" target=\"_blank\" rel=\"noindex nofollow\">Aluminum alloys 5052 and 6061 appear in lightweight panels and chassis where weight reduction matters<\/a>. Aluminum provides natural corrosion resistance and stronger thermal conductivity. It carries a higher material cost and different forming behavior, which calls for fabrication expertise.<\/p>\n<h3>Common Finishes<\/h3>\n<ul>\n<li><strong>Powder coating:<\/strong> The standard finish for indoor cabinets that delivers durability and consistent appearance. <a href=\"https:\/\/bwsheetmetal.com\/data-center-server-rack-design\" target=\"_blank\" rel=\"noindex nofollow\">Dry-film thickness in the 60\u2013100 \u00b5m range is a common reference, with final acceptance set by drawings and supplier datasheets<\/a>.<\/li>\n<li><strong>Zinc plating:<\/strong> A frequent choice for mounting rails and hardware that need corrosion resistance.<\/li>\n<li><strong>Masking for electrical continuity:<\/strong> <a href=\"https:\/\/mjmmfg.com\/data-center-sheet-metal-fabrication\" target=\"_blank\" rel=\"noindex nofollow\">Powder coating insulates surfaces, so ground stud locations require masking before finishing to preserve bare metal contact<\/a>.<\/li>\n<\/ul>\n<p>The right combination of material and finish depends on deployment environment, load requirements and budget. A precision fabricator can guide teams through these trade-offs during the DFM phase.<\/p>\n<figure style=\"text-align: center\"><img decoding=\"async\" src=\"https:\/\/cdn.aigrowthmarketer.co\/1785163025306-7525a9a10f59.webp\" alt=\"Powder-coating and material-handling racks on the Fabcon shop floor.\" style=\"max-height: 500px\" loading=\"lazy\"><figcaption><em>In-house finishing \u2014 powder coat, wet paint, silkscreen, and CARC mil-spec coating \u2014 keeps cosmetic standards consistent and removes a supplier handoff from the build.<\/em><\/figcaption><\/figure>\n<h2>Thermal Management for High-Density Cabinets<\/h2>\n<p>Thermal management is the defining challenge for modern data center cabinets. As rack densities push beyond 20 kW, airflow design becomes a precision engineering problem, and AI deployments are driving thresholds even higher.<\/p>\n<h3>Perforated Door Open Area<\/h3>\n<p><a href=\"https:\/\/kdstelectrical.com\/data-center-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">For racks up to 8 kW, door perforation of at least 60 percent open area is recommended, and for 10\u201330 kW racks, 70\u201380 percent open area is required<\/a>. <a href=\"https:\/\/cisco.com\/c\/en\/us\/td\/docs\/switches\/datacenter\/nexus9000\/hw\/n9164E-NS4-O\/cisco-n9164e-ns4-o-hardware-installation-guide\/rack-specs\/rack-specs-perforated.html\" target=\"_blank\" rel=\"noindex nofollow\">Cisco rack specifications call for at least 60 percent open area on front and rear doors and at least 15 square inches of open area per rack unit of door height<\/a>.<\/p>\n<h3>Airflow Baffles and Blanking Panels<\/h3>\n<p>Precision fabrication supports custom airflow solutions such as baffles, ducting and blanking panels that direct cool air to equipment inlets and block hot air recirculation. <a href=\"https:\/\/kdstelectrical.com\/42u-server-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">Many data centers operate without blanking panels, which reduces cooling effectiveness and can raise inlet temperatures through recirculation<\/a>.<\/p>\n<h3>Liquid Cooling Support<\/h3>\n<p><a href=\"https:\/\/electronics.alibaba.com\/buyingguides\/server-cabinet-cooling-guide-2026\" target=\"_blank\" rel=\"noindex nofollow\">Liquid cooling now plays a central role for rack densities above 30 kW<\/a>. Cabinets must include provisions for plumbing interfaces. They also need reinforced structures to handle added weight and layouts compatible with manifolds and coolant distribution units. <a href=\"https:\/\/electronics.alibaba.com\/buyingguides\/server-cabinet-cooling-guide-2026\" target=\"_blank\" rel=\"noindex nofollow\">Direct-to-chip liquid cooling increases weight per rack<\/a>. Structural reinforcement must appear in the initial design rather than as a retrofit.<\/p>\n<p>Precision sheet metal fabrication enables these thermal solutions, from hex perforation patterns that maximize open area while preserving strength to custom mounting provisions for rear-door heat exchangers. Achieving these solutions efficiently requires close attention to design for manufacturability.<\/p>\n<h2>Design for Manufacturability (DFM) for Data Center Cabinets<\/h2>\n<p>DFM is where precision fabrication partners deliver the most value. Early collaboration between engineering teams and a fabricator\u2019s DFM specialists reduces rework, improves cost efficiency and supports smooth scaling from prototype to production.<\/p>\n<p>Common DFM mistakes to avoid include several recurring issues.<\/p>\n<ul>\n<li><strong>Tolerance stack-up in tall frames:<\/strong> <a href=\"https:\/\/mjmmfg.com\/data-center-sheet-metal-fabrication\" target=\"_blank\" rel=\"noindex nofollow\">A 42U frame involves multiple stacked bends, and if each bend drifts by five thousandths in the same direction, mounting holes at the top can land a quarter inch from the print<\/a>. Accurate bend deduction per material, gauge and tool is essential.<\/li>\n<li><strong>Inadequate weld design:<\/strong> Weld sequence and fixturing control frame squareness, and poor planning allows heat distortion to damage dimensional accuracy.<\/li>\n<li><strong>Hardware insertion oversights:<\/strong> <a href=\"https:\/\/factorem.co\/capabilities\/sheet-metal\" target=\"_blank\" rel=\"noindex nofollow\">PEM fasteners and weld nuts need clearance from bends and edges, typically three times their outer diameter, to avoid deformation during forming<\/a>.<\/li>\n<li><strong>EMI or RFI shielding gaps:<\/strong> Cabinets for sensitive equipment need seam tolerances and conductive gasket provisions defined early.<\/li>\n<li><strong>Grounding continuity:<\/strong> <a href=\"https:\/\/bwsheetmetal.com\/data-center-server-rack-design\" target=\"_blank\" rel=\"noindex nofollow\">Surface finish functions as part of joint design<\/a>, so bonding contact points must be masked before coating.<\/li>\n<\/ul>\n<p>Key considerations for an RFQ:<\/p>\n<ul>\n<li>Specify critical tolerances on rail spacing, frame squareness and door alignment<\/li>\n<li>Define weld quality requirements and inspection protocols<\/li>\n<li>Identify hardware insertion locations and types<\/li>\n<li>Address EMI or RFI shielding requirements when relevant<\/li>\n<li>Specify finish requirements, including masking for electrical bonding points<\/li>\n<\/ul>\n<p>A fabricator with in-house engineering can review drawings, flag potential issues and suggest improvements before production begins. That support saves weeks of rework and reduces scrap costs.<\/p>\n<p><a href=\"https:\/\/fabcon.com\/\" target=\"_blank\"><strong>Start a DFM review with Fabcon\u2019s engineering team.<\/strong><\/a><\/p>\n<h2>How to Choose a Precision Sheet Metal Fabricator for Data Center Cabinets<\/h2>\n<p>Selecting the right fabrication partner is as critical as the cabinet design itself. Evaluate these key criteria.<\/p>\n<h3>Certifications and Quality Systems<\/h3>\n<ul>\n<li><strong>ISO 9001:2015<\/strong> signals a mature quality management system for commercial and industrial work.<\/li>\n<li><strong>AS9100D<\/strong> adds aerospace-grade requirements such as configuration management, risk management, counterfeit part prevention and enhanced supplier controls, which align with mission-critical data center needs.<\/li>\n<li><strong>ITAR registration<\/strong> supports defense or government deployments.<\/li>\n<\/ul>\n<p><a href=\"https:\/\/connect981.com\/faqs\/how-does-as9100-affect-supplier-quality-management\" target=\"_blank\" rel=\"noindex nofollow\">For buyers of data center cabinets, AS9100 certification indicates disciplined procurement, traceability and change-control processes<\/a>, especially when cabinets involve critical or customer-specific requirements. Fabcon holds ISO 9001:2015 and AS9100D certifications and is ITAR registered, with quality systems governing every stage of the build.<\/p>\n<h3>Vertical Integration<\/h3>\n<p>Vendor handoffs often create supply chain friction. When fabrication, finishing and assembly sit with different suppliers, coordination overhead, quality disputes and lead time variability increase. <a href=\"https:\/\/mjmmfg.com\/how-to-choose-the-right-sheet-metal-fabrication-supplier\" target=\"_blank\" rel=\"noindex nofollow\">Single-source fabrication, where cutting, forming, welding, machining and finishing happen under one roof, provides one point of accountability and reduces markup, lead time and handoff errors<\/a>.<\/p>\n<p>Fabcon\u2019s manufacturing space spans engineering, fabrication, machining, finishing and assembly, which supports single-source accountability from prototype through production.<\/p>\n<figure style=\"text-align: center\"><img decoding=\"async\" src=\"https:\/\/cdn.aigrowthmarketer.co\/1785163005561-2aaf42271e34.webp\" alt=\"Wide view of the Fabcon precision sheet-metal fabrication floor with machining equipment.\" style=\"max-height: 500px\" loading=\"lazy\"><figcaption><em>Founded in 1977, Fabcon runs 220,000 sq ft of vertically integrated fabrication across two Southern California facilities \u2014 engineering, machining, fabrication, finishing, and assembly under one roof.<\/em><\/figcaption><\/figure>\n<h3>Scalable Capacity With Flexible Production<\/h3>\n<p>Large global contract manufacturers provide scale, yet high minimums and long onboarding can slow programs. Job shops often deliver flexibility, although limited capacity restricts growth. The ideal partner supports a program as it grows from quick-turn prototypes to mid-volume production without forcing rigid production lines. Fabcon\u2019s agile production cells adapt to changing volumes, mixed SKUs and evolving BOMs.<\/p>\n<figure style=\"text-align: center\"><img decoding=\"async\" src=\"https:\/\/cdn.aigrowthmarketer.co\/1785163127416-faf90adc826f.webp\" alt=\"A black open-frame metal chassis and rack structure.\" style=\"max-height: 500px\" loading=\"lazy\"><figcaption><em>Custom chassis, racks, and structural frames \u2014 fabricated, finished, and assembled by one accountable partner, so a program moves from bare frame to finished build without vendor handoffs.<\/em><\/figcaption><\/figure>\n<h3>Engineering Support<\/h3>\n<p><a href=\"https:\/\/mjmmfg.com\/how-to-choose-the-right-sheet-metal-fabrication-supplier\" target=\"_blank\" rel=\"noindex nofollow\">Total landed cost, including freight, rejects, rework, delays and supplier management, matters more than the lowest per-part price when choosing a fabrication supplier<\/a>. A fabricator that reviews drawings, asks focused questions and flags DFM issues early delivers stronger long-term value.<\/p>\n<h2>Emerging Trends: AI and High-Density Racks<\/h2>\n<p>AI workloads are reshaping data center cabinet requirements. <a href=\"https:\/\/kdstelectrical.com\/data-center-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">An NVIDIA H100 GPU draws 700 W per chip in its SXM5 form<\/a>. <a href=\"https:\/\/kdstelectrical.com\/data-center-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">Newer B200 chips approach 1,000 W<\/a>. <a href=\"https:\/\/kdstelectrical.com\/data-center-rack-cabinet\" target=\"_blank\" rel=\"noindex nofollow\">A single 42U cabinet with eight GPU servers easily clears 25\u201330 kW, and full HGX-class clusters approach 130 kW<\/a>.<\/p>\n<p>These shifts drive several fabrication priorities.<\/p>\n<ul>\n<li><strong>Stronger structures:<\/strong> Higher power densities increase equipment weight, so cabinets must support higher static loads while holding tight dimensions.<\/li>\n<li><strong>Advanced thermal management:<\/strong> <a href=\"https:\/\/yplasma.tech\/blog\/data-center-thermal-management\" target=\"_blank\" rel=\"noindex nofollow\">Air cooling alone fails above 30\u201350 kW per rack<\/a>. Cabinets need provisions for liquid cooling manifolds, rear-door heat exchangers and hybrid cooling approaches.<\/li>\n<li><strong>Modular designs:<\/strong> As AI infrastructure evolves, cabinets must accept configuration changes without full redesigns.<\/li>\n<li><strong>Integrated power distribution:<\/strong> High-density racks require space and mounting for high-capacity PDUs and modular busbar systems. <a href=\"https:\/\/electronics.alibaba.com\/buyingguides\/server-cabinet-cooling-guide-2026\" target=\"_blank\" rel=\"noindex nofollow\">Modular busbar systems now appear in many new data center projects<\/a>, which supports rapid reconfiguration of power and cooling circuits.<\/li>\n<\/ul>\n<p>Fabcon\u2019s agile production model supports this evolution and accommodates design changes and configuration shifts that define AI-driven infrastructure.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3>What is the standard size for a data center cabinet?<\/h3>\n<p>As noted earlier, the EIA-310 standard defines the 19-inch mounting width and 1.75-inch rack unit height. Common cabinet configurations include 42U and 48U heights, widths of 600\u2013800 mm and depths from 600 mm to 1,200 mm. For modern high-density deployments, depths of 1,000\u20131,200 mm support deeper servers, cable management and PDU clearance. Ceiling height and floor load capacity should be confirmed before specifying 48U configurations.<\/p>\n<h3>What materials are used for data center cabinets?<\/h3>\n<p>Cold-rolled steel is the standard baseline material for structural frames and load-bearing components because it balances strength and cost. Aluminum alloys such as 5052 and 6061 support lightweight panels and thermal-management components where weight reduction is a priority. Galvanized steel adds corrosion resistance for selected sub-components. Stainless steel appears in aggressive environments where its cost premium aligns with performance needs.<\/p>\n<h3>What open area percentage is required for perforated cabinet doors?<\/h3>\n<p>As discussed in the thermal management section, recommended open area ranges from 60 percent for lower-density racks to 70\u201380 percent for higher-density racks. Cisco specifies a minimum 60 percent open area on front and rear doors and at least 15 square inches of open area per rack unit of door height. Hex perforation patterns often provide more open area than round patterns at the same pitch while preserving structural integrity.<\/p>\n<h3>How does AS9100 certification benefit data center cabinet sourcing?<\/h3>\n<p>AS9100 incorporates all ISO 9001 requirements and adds aerospace-specific controls such as formal risk management, strict change management, counterfeit part prevention and enhanced supplier evaluation. For data center cabinets that support mission-critical infrastructure, AS9100 certification signals disciplined procurement, traceability and change-control processes. Buyers should confirm that the certificate scope covers the specific work being placed, because certification scope varies by facility and registration body.<\/p>\n<h3>What are the most common DFM mistakes in data center cabinet fabrication?<\/h3>\n<p>Tolerance stack-up in tall frames appears frequently. Multiple stacked bends in a 42U frame can push mounting holes significantly off-print when each forming operation drifts in the same direction. Other common mistakes include poor weld sequence planning that distorts frames, hardware insertion oversights where PEM fasteners sit too close to bends, missing EMI or RFI shielding provisions and unmasked ground stud locations before powder coating. Early DFM collaboration with a fabricator that reviews drawings before production addresses these issues.<\/p>\n<h2>The Right Partner for Precision Data Center Cabinets<\/h2>\n<p>Precision sheet metal data center cabinets form the structural and thermal foundation of modern data center infrastructure. As rack densities escalate and AI workloads push thermal and structural limits, the precision of a fabrication partner shapes performance, reliability and time-to-market.<\/p>\n<p>The market presents a spectrum, from job shops with limited capacity to global contract manufacturers with rigid processes. Fabcon occupies the middle ground and combines engineering depth, vertical integration and responsive support.<\/p>\n<p>From DFM collaboration and precision fabrication to in-house finishing and electromechanical assembly, Fabcon provides single-source accountability that reduces vendor handoffs, compresses lead times and supports consistent quality from prototype through production.<\/p>\n<p><a href=\"https:\/\/fabcon.com\/\" target=\"_blank\"><strong>Contact Fabcon to discuss a data center cabinet program.<\/strong><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Fabcon delivers precision-fabricated data center cabinets built for thermal performance and scale. Engineering support and flexible capacity included.<\/p>\n","protected":false},"author":69,"featured_media":748,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[8],"tags":[],"class_list":["post-749","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sheet-metal-fabrication"],"_links":{"self":[{"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/posts\/749","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/comments?post=749"}],"version-history":[{"count":1,"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/posts\/749\/revisions"}],"predecessor-version":[{"id":1471,"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/posts\/749\/revisions\/1471"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/media\/748"}],"wp:attachment":[{"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/media?parent=749"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/categories?post=749"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fabcon.com\/articles\/wp-json\/wp\/v2\/tags?post=749"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}